安装包 下载地址 。
https://www.lmlphp.com/r?x=CtQ9ytoWsjbjPLy64Mr9CtKN2LIryxIVzAQrzA86PMbdsMIjPL3wsL3-PEwAPMb64jb9zMbmyjbdPLI94LgVFEKAPTImCFa6ofy6oFX62ekjsx2W5tOwp8
安装过程

首先下载获取安装包

解压

$ tar -zxf MegaCli8.07.10.tar.gz
$ cd MegaCli8.07.10/Linux/
$ rpm -ivh Lib_Utils-1.00-09.noarch.rpm MegaCli-8.02.21-1.noarch.rpm

加入系统环境

$ ln -s /opt/MegaRAID/MegaCli/MegaCli64 /usr/local/bin/MegaCli
$ MegaCli -v
MegaCLI SAS RAID Management Tool Ver 8.02.21 Oct 21, 2011

(c)Copyright 2011, LSI Corporation, All Rights Reserved.

Exit Code: 0x00

安装完成!

冲突处理:

$ rpm -ivh Lib_Utils-1.00-09.noarch.rpm MegaCli-8.02.21-1.noarch.rpm
准备中… ################################# [100%]
file /opt/lsi/3rdpartylibs/x86_64/libsysfs.so.2.0.2 from install of Lib_Utils-1.00-09.noarch conflicts with file from package srvadmin-storelib-sysfs-9.1.0-2757.12163.el7.x86_64
原因: Lib_Utils和Dell服务器自带的包srvadmin冲突,直接将其卸载,然后安装即可。

rpm -e srvadmin-storelib-sysfs-9.1.0-2757.12163.el7.x86_64 –nodeps
使用指南
基本用法

查raid级别

$ megacli -LDInfo -Lall -aALL

查raid卡信息

$ megacli -AdpAllInfo -aALL

查看硬盘信息

$ megacli -PDList -aALL

查看电池信息

$ megacli -AdpBbuCmd -aAll

查看raid卡日志

$ megacli -FwTermLog -Dsply -aALL

显示适配器个数

$ megacli -adpCount

显示适配器时间

$ megacli -AdpGetTime –aALL

显示所有适配器信息

$ megacli -AdpAllInfo -aAll

显示所有逻辑磁盘组信息

$ megacli -LDInfo -LALL -aAll

显示所有的物理信息

$ megacli -PDList -aAll

查看充电状态

$ megacli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’

显示BBU状态信息

$ megacli -AdpBbuCmd -GetBbuStatus -aALL

显示BBU容量信息

$ megacli -AdpBbuCmd -GetBbuCapacityInfo -aALL

显示BBU设计参数

$ megacli -AdpBbuCmd -GetBbuDesignInfo -aALL

显示当前BBU属性

$ megacli -AdpBbuCmd -GetBbuProperties -aALL

显示Raid卡型号,Raid设置,Disk相关信息

$ megacli -cfgdsply -aALL    

磁带状态的变化,从拔盘,到插盘的过程中。

Device |Normal |Damage |Rebuild |Normal
Virtual Drive |Optimal|Degraded|Degraded|Optimal
Physical Drive |Online |Failed Unconfigured|Rebuild|Online

查看物理磁盘状态:

$ megacli -PDRbld -ShowProg -PhysDrv  [Enclosure Device ID:Slot Number]  -a0

Rebuild 中的物理磁盘状态中会显示:”Firmware state: Rebuild”

查询 Rebuild 进度:

$ megacli -pdrbld -showprog -physdrv[E:S] -aALL

返回内容类似于下面这样:

Rebuild Progress on Device at Enclosure 32, Slot 5 Completed 77% in 101 Minutes.

以文本进度条样式显示 Rebuild 进度:

$ megacli -pdrbld -progdsply -physdrv[E:S] -aALL

屏幕显示类似下面的内容:

Rebuild progress of physical drives…
Enclosure:Slot Percent Complete Time Elps
032 :05 #######################87 %################*** 01:59:07
Press key to quit…

查看 RAID 卡 Rebuild 参数:

$ megacli -AdpAllinfo -aALL | grep -i rebuild

返回结果类似下面这样

Rebuild Rate : 30%
Auto Rebuild : Enabled
Rebuild Rate : YesForce
Rebuild : Yes

设置 RAID 卡 Rebuild 比例为60%:

$ megacli -AdpSetProp { RebuildRate -60} -aALL

设置成功后返回:

Adapter 0: Set rebuild rate to 60% success.
MegaCLI使用方法:http://blog.51cto.com/daixuan/1863567

重要参数
Firmware state 磁盘状态
Firmware state: Online, Spun Up 磁盘正常
Firmware state: Unconfigured(good), Spun Up 磁盘已安装,但未启用
Firmware state: Unconfigured(bad) 故障, 对应hwcheck的 Non-Critical
Firmware state: Failed 故障, 对应hwcheck的Critical
Firmware state: Rebuild 重建,一般在更换磁盘时显示
Enclosure Device ID: 32 设备
Slot Number: 1 磁盘在服务器上的槽位
Adapter #0 适配器编号,对应 -a 参数
实战:raid10环境下替换硬盘
Raid10环境下换硬盘还是很简单的,支持热插拔,直接拔下换掉就可以了,下面是操作步骤。

主要环境
服务器: R720

系统: CentOS7

raid类型:raid10

查看硬盘信息

为了更加清楚的呈现操作过程,未对信息简化处理。

$ MegaCli -PDList -aAll -NoLog

Adapter #0

Enclosure Device ID: 32
Slot Number: 0
Drive’s postion: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: 0
Device Id: 0
WWN: 5000C50076CD09B4
Sequence Number: 1
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 28
Last Predictive Failure Event Seq Number: 4378
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Firmware state: Unconfigured(good), Spun Up
Device Firmware Level: ES66
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50076cd09b5
SAS Address(1): 0x0
Connected Port Number: 5(path0)
Inquiry Data: SEAGATE ST3600057SS ES666SL8SASQ
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: Foreign
Foreign Secure: Drive is not secured by a foreign lock key
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :40C (104.00 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive’s write cache : Disabled
Port-0 :
Port status: Active
Port’s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port’s Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : Yes

Enclosure Device ID: 32
Slot Number: 2
Enclosure position: 0
Device Id: 2
WWN: 5000C50076CD05BC
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 0 KB [0x0 Sectors]
Non Coerced Size: 0 KB [0x0 Sectors]
Coerced Size: 0 KB [0x0 Sectors]
Firmware state: Unconfigured(bad)
Device Firmware Level: ES66
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50076cd05bd
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: SEAGATE ST3600057SS ES666SL8SAVC
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: Unknown
Link Speed: Unknown
Media Type: Hard Disk Device
Drive: Not Supported
Drive Temperature :0C (32.00 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive’s write cache : Disabled
Port-0 :
Port status: Active
Port’s Linkspeed: Unknown
Port-1 :
Port status: Active
Port’s Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32
Slot Number: 1
Drive’s postion: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: 0
Device Id: 1
WWN: 5000C500983873BC
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: VT31
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c500983873bd
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: SEAGATE ST600MP0005 VT31S7M1CSLT
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: Unknown
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :41C (105.80 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive’s write cache : Disabled
Port-0 :
Port status: Active
Port’s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port’s Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32
Slot Number: 3
Drive’s postion: DiskGroup: 0, Span: 1, Arm: 1
Enclosure position: 0
Device Id: 3
WWN: 5000C50076CE2F30
Sequence Number: 2
Media Error Count: 5
Other Error Count: 71
Predictive Failure Count: 15
Last Predictive Failure Event Seq Number: 4379
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: ES66
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50076ce2f31
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: SEAGATE ST3600057SS ES666SL8SAKA
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :48C (118.40 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive’s write cache : Disabled
Port-0 :
Port status: Active
Port’s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port’s Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : Yes

Enclosure Device ID: 32
Slot Number: 4
Drive’s postion: DiskGroup: 1, Span: 0, Arm: 0
Enclosure position: 0
Device Id: 4
WWN: 5000C5007E70F0F8
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: ES66
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007e70f0f9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST3600057SS ES666SL9F1JB
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :46C (114.80 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive’s write cache : Disabled
Port-0 :
Port status: Active
Port’s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port’s Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32
Slot Number: 5
Drive’s postion: DiskGroup: 1, Span: 0, Arm: 1
Enclosure position: 0
Device Id: 5
WWN: 5000C5007E708E3C
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: ES66
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5007e708e3d
SAS Address(1): 0x0
Connected Port Number: 4(path0)
Inquiry Data: SEAGATE ST3600057SS ES666SL9F2RB
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :45C (113.00 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Drive’s write cache : Disabled
Port-0 :
Port status: Active
Port’s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port’s Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No

Exit Code: 0x00
由以上信息可知该服务器有6块磁盘(Device Id)。

卸载故障硬盘

$ MegaCli -PDOffline -PhysDrv[32:2] -a0
$ MegaCli -PDOffline -PhysDrv[32:0] -a0

上面命令中 32 和 2 以及 -a0 的对应关系:

Adapter #0
Enclosure Device ID: 32
Slot Number: 2
替换故障硬盘
此时故障硬盘已经OFFLINE,在服务器现场查看时,故障硬盘闪烁的是黄灯,正常硬盘的绿灯; 拔下故障硬盘,插上好硬盘,硬盘灯闪烁为绿色,并硬盘快速旋转,表示硬盘正在rebuild状态,查看状态如下:

$ MegaCli -PDList -aAll -NoLog


Enclosure Device ID: 32
Slot Number: 3

Firmware state: Rebuild

查看rebuild进度
$ MegaCli -PDRbld -ShowProg -PhysDrv[32:2] -aAll

Rebuild Progress on Device at Enclosure 32, Slot 3 Completed 16% in 94 Minutes.
磁盘更换完成
$ MegaCli -PDList -aAll -NoLog | grep ‘Firmware state’
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up

文档更新时间: 2023-01-18 12:48   作者:月影鹏鹏
IT运维支持-AIWALY-月影工作室